Products
The HY-A series of air-cooled heat pump chillers are widely applicable to air conditioning projects for both newly built and renovated industrial and civil buildings of various sizes, such as hotels, apartments, restaurants, office buildings, shopping malls, cinemas, factories, hospitals, and more. They are an ideal choice particularly for projects with higher requirements for noise control and the surrounding environment, as well as those where it is inconvenient to install boilers, cooling towers, or cooling water pumps.
High efficiency and energy saving, low operating cost:
Transfer heat through heat pump technology instead of directly consuming energy. In winter heating, the coefficient of performance (COP) can usually reach more than 3.0, that is, 1 unit of electricity can generate 3 times the thermal energy, which significantly saves energy.
Environmental Protection, Water Conservation, Green and Low - carbon:
It relies entirely on air cooling, which is suitable for water - scarce areas or projects with water resource limitations,uses environmentally friendly refrigerants (such as R410A, R134a), reducing greenhouse gas emissions and meeting the requirements of environmental protection regulations.
Intelligent Control and Automation:
Supports Internet of Things (IoT) access, monitors operating status in real - time, and realizes fault early warning and energy - efficiency analysis.Automatically switches between cooling/heating modes according to the set temperature, reducing manual intervention.
Parameters of Single - head Air - cooled Heat Pump
Model: HY-AD-RB | 270 | 370 | 440 | 530 | 590 | 660 | ||
Refrigeration capacity | KW | 272 | 372 | 442 | 524 | 585 | 662 | |
RT | 77 | 106 | 126 | 149 | 166 | 188 | ||
kcal/h | 233920 | 319920 | 380120 | 450640 | 503100 | 569320 | ||
Heat recovery amount | KW | 82 | 112 | 133 | 157 | 176 | 199 | |
Refrigeration input power | KW | 83.4 | 113.3 | 133.5 | 158 | 176 | 199.5 | |
Refrigeration rated current | A | 155 | 206 | 244 | 274 | 310 | 350 | |
Heating capacity | KW | 316.0 | 435.0 | 524.0 | 618.0 | 681.0 | 776.0 | |
RT | 90 | 124 | 149 | 176 | 194 | 221 | ||
kcal/h | 271760 | 374100 | 450640 | 531480 | 585660 | 667360 | ||
Heating input power | KW | 81 | 109.5 | 129.2 | 151.7 | 170 | 193.2 | |
Heating rated current | A | 150 | 200 | 235 | 264 | 300 | 338 | |
Maximum operating current | A | 222 | 297 | 348 | 393 | 441 | 501 | |
Maximum distribution current | KW | 108 | 147 | 174 | 205 | 229 | 259 | |
Main power supply | 380V/3P/50HZ | |||||||
Refrigeran | R22/R407C | |||||||
Compressor | Form | / | Semi-enclosed double-screw type | |||||
Startup method | / | Y-△stating | ||||||
Energy regulation | % | 25%-100%stepless adjustment | ||||||
Side heat exchanger | Form | / | High-effciency shell-and-tube | |||||
Refrigeration water flow | 46.8 | 64.0 | 76.0 | 90.1 | 100.6 | 113.9 | ||
Hot water flow rate | m3/h | 54.3 | 74.8 | 90.1 | 106.5 | 117.2 | 133.7 | |
Water resistance | Kpa | 52 | 54 | 56 | 57 | 59 | 62 | |
In and out water pipes | DN | 100 | 100 | 125 | 125 | 125 | 150 | |
Aricraft exterior dimensions | Long | MM | 3150 | 4150 | 4680 | 4680 | 5620 | 5620 |
Wide | MM | 2260 | 2260 | 2260 | 2260 | 2260 | 2260 | |
High | MM | 2520 | 2520 | 2520 | 2520 | 2520 | 2520 | |
Aircraft weight | KG | 3180 | 3900 | 4440 | 5140 | 6000 | 6250 | |
Operating weight | KG | 3320 | 4150 | 4640 | 5400 | 6250 | 6580 |
Parameters of air - cooled heat pump with dual - head
Model: HY-AD-RB | 650 | 750 | 810 | 880 | 960 | 1050 | 1100 | 1170 | 1250 | 1300 | ||
Refrigeration capacity | KW | 646 | 744 | 813 | 882 | 966 | 1045 | 1106 | 1168 | 1247 | 1283 | |
RT | 184 | 212 | 231 | 251 | 275 | 297 | 314 | 332 | 355 | 365 | ||
kcal/h | 555560 | 639840 | 699180 | 758520 | 830760 | 898700 | 951160 | 1004480 | 1072420 | 1103380 | ||
Refrigeration input power | KW | 195 | 226.6 | 246.8 | 267 | 291.4 | 316 | 334 | 352.1 | 376 | 386 | |
Refrigeration rated current | A | 356 | 412 | 450 | 490 | 520 | 550 | 585 | 619 | 659 | 700 | |
Heating capacity | KW | 750.0 | 869.0 | 959.0 | 1047.0 | 1142.0 | 1238.0 | 1299.0 | 1361.0 | 1456.0 | 1507.0 | |
RT | 213 | 247 | 273 | 298 | 325 | 352 | 369 | 387 | 414 | 428 | ||
kcal/h | 645000 | 747340 | 824740 | 900420 | 982120 | 1064680 | 1117140 | 1170460 | 1252160 | 1296020 | ||
Heating input power | KW | 188.8 | 219 | 238.7 | 258.4 | 281 | 304 | 321.7 | 340 | 364 | 376 | |
Heating rated current | A | 344 | 398 | 434 | 472 | 500 | 528 | 563 | 598 | 636 | 674 | |
Maximum operating current | A | 514 | 594 | 645 | 697 | 742 | 787 | 834 | 882 | 942 | 1002 | |
Maximum distribution current | KW | 254 | 296 | 321 | 347 | 380 | 412 | 435 | 458 | 488 | 502 | |
Main power supply | 380V/3P/50HZ | |||||||||||
Refrigeran | R22/R407C | |||||||||||
Compressor | Form | / | Semi-enclosed double-screw type | |||||||||
Startup method | / | Y-△stating | ||||||||||
Energy regulation | % | 25%-100%stepless adjustment | ||||||||||
Side heat exchanger | Form | / | High-effciency shell-and-tube | |||||||||
Refrigeration water flow | 111.0 | 127.8 | 139.7 | 151.6 | 166.0 | 179.6 | 190.1 | 200.7 | 214.3 | 220.5 | ||
Hot water flow rate | 128.9 | 149.3 | 164.8 | 179.9 | 196.2 | 212.7 | 223.2 | 233.9 | 250.2 | 259.0 | ||
Water resistance | Kpa | 62 | 63 | 65 | 66 | 71 | 73 | 75 | 77 | 77 | 78 | |
In and out water pipes | DN | 150 | 200 1182 | |||||||||
Aricraft exterior dimensions | Long | MM | 6550 | 8350 | 9250 | 9250 | 9250 | 10200 | 11200 | 11200 | 11200 | 11200 |
Wide | MM | 2260 | 2260 | 2260 | 2260 | 2260 | 2260 | 2260 | 2260 | 2260 | 2260 | |
High | MM | 2520 | 2520 | 2520 | 2520 | 2520 | 2520 | 2520 | 2520 | 2520 | 2520 | |
Aircraft weight | KG | 7400 | 8000 | 8300 | 8500 | 9400 | 10500 | 11000 | 11600 | 12000 | 12800 | |
Operating weight | KG | 7750 | 8300 | 8660 | 8900 | 9900 | 11000 | 11500 | 12200 | 12700 | 13500 |