The HY-A series of air-cooled heat pump chillers are widely applicable to air conditioning projects for both newly built and renovated industrial and civil buildings of various sizes, such as hotels, apartments, restaurants, office buildings, shopping malls, cinemas, factories, hospitals, and more. They are an ideal choice particularly for projects with higher requirements for noise control and the surrounding environment, as well as those where it is inconvenient to install boilers, cooling towers, or cooling water pumps.
Product details

Product Description:

The HY-A series of air-cooled heat pump chillers are widely applicable to air conditioning projects for both newly built and renovated industrial and civil buildings of various sizes, such as hotels, apartments, restaurants, office buildings, shopping malls, cinemas, factories, hospitals, and more. They are an ideal choice particularly for projects with higher requirements for noise control and the surrounding environment, as well as those where it is inconvenient to install boilers, cooling towers, or cooling water pumps.

Product Features:

High efficiency and energy saving, low operating cost:

Transfer heat through heat pump technology instead of directly consuming energy. In winter heating, the coefficient of performance (COP) can usually reach more than 3.0, that is, 1 unit of electricity can generate 3 times the thermal energy, which significantly saves energy.

Environmental Protection, Water Conservation, Green and Low - carbon:

It relies entirely on air cooling, which is suitable for water - scarce areas or projects with water resource limitations,uses environmentally friendly refrigerants (such as R410A, R134a), reducing greenhouse gas emissions and meeting the requirements of environmental protection regulations.

Intelligent Control and Automation:

Supports Internet of Things (IoT) access, monitors operating status in real - time, and realizes fault early warning and energy - efficiency analysis.Automatically switches between cooling/heating modes according to the set temperature, reducing manual intervention.

Parameter Table:

Parameters of Single - head Air - cooled Heat Pump

Model: HY-AD-RB

270

370

440

530

590

660

Refrigeration capacity

KW

272

372

442

524

585

662

RT

77

106

126

149

166

188

kcal/h

233920

319920

380120

450640

503100

569320

Heat recovery amount

KW

82

112

133

157

176

199

Refrigeration input power

KW

83.4

113.3

133.5

158

176

199.5

Refrigeration rated current

A

155

206

244

274

310

350

Heating capacity

KW

316.0

435.0

524.0

618.0

681.0

776.0

RT

90

124

149

176

194

221

kcal/h

271760

374100

450640

531480

585660

667360

Heating input power

KW

81

109.5

129.2

151.7

170

193.2

Heating rated current

A

150

200

235

264

300

338

Maximum operating current

A

222

297

348

393

441

501

Maximum distribution current

KW

108

147

174

205

229

259

Main power supply

380V/3P/50HZ

Refrigeran

R22/R407C

Compressor

Form

/

Semi-enclosed double-screw type

Startup method

/

Y-△stating

Energy regulation

%

25%-100%stepless adjustment

Side heat exchanger

Form

/

High-effciency shell-and-tube

Refrigeration water flow


46.8

64.0

76.0

90.1

100.6

113.9

Hot water flow rate

m3/h

54.3

74.8

90.1

106.5

117.2

133.7

Water resistance

Kpa

52

54

56

57

59

62

In and out water pipes

DN

100

100

125

125

125

150

Aricraft exterior dimensions

Long

MM

3150

4150

4680

4680

5620

5620

Wide

MM

2260

2260

2260

2260

2260

2260

High

MM

2520

2520

2520

2520

2520

2520

Aircraft weight

KG

3180

3900

4440

5140

6000

6250

Operating weight

KG

3320

4150

4640

5400

6250

6580

Parameters of air - cooled heat pump with dual - head

Model: HY-AD-RB

650

750

810

880

960

1050

1100

1170

1250

1300

Refrigeration capacity

KW

646

744

813

882

966

1045

1106

1168

1247

1283

RT

184

212

231

251

275

297

314

332

355

365

kcal/h

555560

639840

699180

758520

830760

898700

951160

1004480

1072420

1103380

Refrigeration input power

KW

195

226.6

246.8

267

291.4

316

334

352.1

376

386

Refrigeration rated current

A

356

412

450

490

520

550

585

619

659

700

Heating capacity

KW

750.0

869.0

959.0

1047.0

1142.0

1238.0

1299.0

1361.0

1456.0

1507.0

RT

213

247

273

298

325

352

369

387

414

428

kcal/h

645000

747340

824740

900420

982120

1064680

1117140

1170460

1252160

1296020

Heating input power

KW

188.8

219

238.7

258.4

281

304

321.7

340

364

376

Heating rated current

A

344

398

434

472

500

528

563

598

636

674

Maximum operating current

A

514

594

645

697

742

787

834

882

942

1002

Maximum distribution current

KW

254

296

321

347

380

412

435

458

488

502

Main power supply

380V/3P/50HZ

Refrigeran

R22/R407C

Compressor

Form

/

Semi-enclosed double-screw type

Startup method

/

Y-△stating

Energy regulation

%

25%-100%stepless adjustment

Side heat exchanger

Form

/

High-effciency shell-and-tube

Refrigeration water flow


111.0

127.8

139.7

151.6

166.0

179.6

190.1

200.7

214.3

220.5

Hot water flow rate


128.9

149.3

164.8

179.9

196.2

212.7

223.2

233.9

250.2

259.0

Water resistance

Kpa

62

63

65

66

71

73

75

77

77

78

In and out water pipes

DN

150

200  1182

Aricraft exterior dimensions

Long

MM

6550

8350

9250

9250

9250

10200

11200

11200

11200

11200

Wide

MM

2260

2260

2260

2260

2260

2260

2260

2260

2260

2260

High

MM

2520

2520

2520

2520

2520

2520

2520

2520

2520

2520

Aircraft weight

KG

7400

8000

8300

8500

9400

10500

11000

11600

12000

12800

Operating weight

KG

7750

8300

8660

8900

9900

11000

11500

12200

12700

13500